DC Motors Test List - We also could design various speeds, torque parameters & dynamic characterics for you if your requirements are not on the following test list.
MODEL
VOLTAGE
NO LOAD
AT MAXIMUM EFFICIENCY
STALLTORQUE
OPERATING
RANGE
NOMINAL
V.DC
SPEED
CURRENT
SPEED
CURRENT
TORQUE
OUTPUT
EFF
rpm
mA
rpm
mA
OZ-IN
g-cm
W
%
OZ-IN
g-cm
HN-48PG-9015T
3-4.8
4.8
15000
2200
12730
9970
3.67
264
34.54
72
24.33
1750
HN-48PG-5042T
4.5-12
6
6000
800
4852
3300
3.61
260
13.40
69
25.0
1800
HN-48PG-2416T
4.5-12
12
6000
100
4340
730
2.15
155
7.05
78
8.33
600
HN-48PG-3510T
6-24
12
6000
350
4985
1300
2.50
180
9.50
64
16.67
1200
HN-48PG-6035T
12-18
12
15400
1000
13330
6190
5.42
390
53.36
71
40.28
2900
HN-48PG-4550T
12-18
12
10000
600
8530
3480
4.44
319
27.95
67
30.14
2170
HN-48PG-26150Y
12-24
12
3600
160
3010
680
2.50
180
5.56
67
30.14
2170
HN-48PG-3510T
6-24
24
6000
200
5195
1000
4.03
290
15.85
70
30.56
2200
HN-48PG-2416Y
12-24
24
7400
80
6580
240
0.97
70
4.74
84
6.94
500
HN-48PG-30100Y
12-24
24
1000
300
8190
1700
4.17
300
26.92
70
31.94
2300
Quick Navigator Menu: (Right-Click again to close this menu.)